Product
UL2586
Application Scope

Used for internal or external connecting lines of general electronic and electrical equipment .

Product Structure

Conductor: Tinned or bare copper 40AWG min.

Insulation: PVC, SRPVC, PE, PP etc.

Shield: AL foil mylar+Tinned or bare conductor braid

Outer sheath: PVC

Flame : Passes UL VW-1, CSA FT1 and JQA -F-Mark test

Highlights

Comply with RoHS,REACH

Characteristic

Drag Chain conform to UL Standards:UL758, UL1581, CSA, C22.2, No.210.2

Properties

Rated temperature:80℃

Rated voltage:600V, 1000V

Technical Data
  • Conductor stranding

    Confirm to UL Standard:UL758, UL1581,CSA C22.2, No.210.2

  • Rated Voltage

    600V, 1000V

  • Temperature Range

    80℃

Concuctor Insulation Shield Constrnuction Jacket MAX.COND Resistance
(Q/m,20°C,DC)
Dielectric strength
(VAC,1min)
AWG
(AWG)
Constrnuctio
(No./mm)
DIA
(mm)
(No.) (mm) Min
average thickness
(mm)
DIA.
Wrap Drain Braid (mm) Min
average thickness
(mm)
DIA.

30

7/0.10

0.30

2

0.76

190

Al-mylar

7/0.10

Tinned coppe

0.76

5.90

381

2000

30

7/0.10

0.30

3

0.76

190

Al-mylar

7/0.10

Tinned coppe

0.76

6.20

381

2000

30

7/0.10

0.30

4

0.76

190

Al-mylar

7/0.10

Tinned coppe

0.76

6.70

381

2000

30

7/0.10

0.30

5

0.76

190

Al-mylar

7/0.10

Tinned coppe

0.76

7.30

381

2000

30

7/0.10

0.30

6

0.76

190

Al-mylar

7/0.10

Tinned coppe

0.76

7.90

381

2000

30

7/0.10

0.30

7

0.76

190

Al-mylar

7/0.10

Tinned coppe

0.76

7.90

381

2000

30

7/0.10

0.30

8

0.76

190

Al-mylar

7/0.10

Tinned coppe

0.76

8.50

381

2000

30

7/0.10

0.30

9

0.76

190

Al-mylar

7/0.10

Tinned coppe

0.76

9.30

381

2000

30

7/0.10

0.30

10

0.76

190

Al-mylar

7/0.10

Tinned coppe

0.76

9.90

381

2000

28

7/0.127

0.38

2

0.76

2.00

Al-mylar

7/0.127

Tinned coppe

0.76

6.20

239

2000

28

7/0.127

0.38

3

0.76

2.00

Al-mylar

7/0.127

Tinned coppe

0.76

6.50

239

2000

28

7/0.127

0.38

4

0.76

2.00

Al-mylar

7/0.127

Tinned coppe

0.76

7.00

239

2000

28

7/0.127

0.38

5

0.76

2.00

Al-mylar

7/0.127

Tinned coppe

0.76

7.60

239

2000

28

7/0.127

0.38

6

0.76

2.00

Al-mylar

7/0.127

Tinned coppe

0.76

8.20

239

2000

28

7/0.127

0.38

7

0.76

2.00

Al-mylar

7/0.127

Tinned coppe

0.76

8.20

239

2000

28

7/0.127

0.38

8

0.76

2.00

Al-mylar

7/0.127

Tinned coppe

0.76

8.90

239

2000

28

7/0.127

0.38

9

0.76

2.00

Al-mylar

7/0.127

Tinned coppe

0.76

9.70

239

2000

28

7/0.127

0.38

10

0.76

2.00

Al-mylar

7/0.127

Tinned coppe

0.76

10.30

239

2000

26

7/0.16

0.48

2

0.76

2.05

Al-mylar

7/0.16

Tinned coppe

0.76

6.30

150

2000

26

7/0.16

0.48

3

0.76

2.05

Al-mylar

7/0.16

Tinned coppe

0.76

6.50

150

2000

26

7/0.16

0.48

4

0.76

2.05

Al-mylar

7/0.16

Tinned coppe

0.76

7.10

150

2000

26

7/0.16

0.48

5

0.76

2.05

Al-mylar

7/0.16

Tinned coppe

0.76

7.80

150

2000

26

7/0.16

0.48

6

0.76

2.05

Al-mylar

7/0.16

Tinned coppe

0.76

8.40

150

2000

26

7/0.16

0.48

7

0.76

2.05

Al-mylar

7/0.16

Tinned coppe

0.76

8.40

150

2000

26

7/0.16

0.48

8

0.76

2.05

Al-mylar

7/0.16

Tinned coppe

0.76

9.10

150

2000

26

7/0.16

0.48

9

0.76

2.05

Al-mylar

7/0.16

Tinned coppe

0.76

9.90

150

2000

26

7/0.16

0.48

10

0.76

2.05

Al-mylar

7/0.16

Tinned coppe

0.76

10.60

150

2000

24

11/0.16

0.61

2

0.76

2.20

Al-mylar

11/0.16

Tinned coppe

0.76

6.60

94.2

2000

24

11/0.16

0.61

3

0.76

2.20

Al-mylar

11/0.16

Tinned coppe

0.76

7.00

94.2

2000

24

11/0.16

0.61

4

0.76

2.20

Al-mylar

11/0.16

Tinned coppe

0.76

7.50

94.2

2000

24

11/0.16

0.61

5

0.76

2.20

Al-mylar

11/0.16

Tinned coppe

0.76

8.20

94.2

2000

24

11/0.16

0.61

6

0.76

2.20

Al-mylar

11/0.16

Tinned coppe

0.76

8.80

94.2

2000

24

11/0.16

0.61

7

0.76

2.20

Al-mylar

11/0.16

Tinned coppe

0.76

8.80

94.2

2000

24

11/0.16

0.61

8

0.76

2.20

Al-mylar

11/0.16

Tinned coppe

0.76

9.50

94.2

2000

24

11/0.16

0.61

9

0.76

2.20

Al-mylar

11/0.16

Tinned coppe

0.76

10.40

94.2

2000

24

11/0.16

0.61

10

0.76

2.20

Al-mylar

11/0.16

Tinned coppe

0.76

11.00

94.2

2000

22

17/0.16

0.76

2

0.76

2.35

Al-mylar

17/0.16

Tinned coppe

0.76

6.90

59.4

2000

22

17/0.16

0.76

3

0.76

2.35

Al-mylar

17/0.16

Tinned coppe

0.76

7.30

59.4

2000

22

17/0.16

0.76

4

0.76

2.35

Al-mylar

17/0.16

Tinned coppe

0.76

7.90

59.4

2000

22

17/0.16

0.76

5

0.76

2.35

Al-mylar

17/0.16

Tinned coppe

0.76

8.60

59.4

2000

22

17/0.16

0.76

6

0.76

2.35

Al-mylar

17/0.16

Tinned coppe

0.76

9.30

59.4

2000

22

17/0.16

0.76

7

0.76

2.35

Al-mylar

17/0.16

Tinned coppe

0.76

9.30

59.4

2000

22

17/0.16

0.76

8

0.76

2.35

Al-mylar

17/0.16

Tinned coppe

0.76

10.10

59.4

2000

22

17/0.16

0.76

9

0.76

2.35

Al-mylar

17/0.16

Tinned coppe

0.76

11.00

59.4

2000

22

17/0.16

0.76

10

0.76

2.35

Al-mylar

17/0.16

Tinned coppe

0.76

11.70

59.4

2000

20

26/0.16

0.94

2

0.76

2.50

Al-mylar

26/0.16

Tinned coppe

0.76

7.30

36.7

2000

20

26/0.16

0.94

3

0.76

2.50

Al-mylar

26/0.16

Tinned coppe

0.76

7.70

36.7

2000

20

26/0.16

0.94

4

0.76

2.50

Al-mylar

26/0.16

Tinned coppe

0.76

8.50

36.7

2000

20

26/0.16

0.94

5

0.76

2.50

Al-mylar

26/0.16

Tinned coppe

0.76

9.30

36.7

2000

20

26/0.16

0.94

6

0.76

2.50

Al-mylar

26/0.16

Tinned coppe

0.76

10.00

36.7

2000

20

26/0.16

0.94

7

0.76

2.50

Al-mylar

26/0.16

Tinned coppe

0.76

10.00

36.7

2000

20

26/0.16

0.94

8

0.76

2.50

Al-mylar

26/0.16

Tinned coppe

0.76

10.80

36.7

2000

20

26/0.16

0.94

9

0.76

2.50

Al-mylar

26/0.16

Tinned coppe

0.76

11.80

36.7

2000

20

26/0.16

0.94

10

0.76

2.50

Al-mylar

26/0.16

Tinned coppe

0.76

12.50

36.7

2000

18

41/0.16

1.18

2

0.76

2.75

Al-mylar

41/0.16

Tinned coppe

0.76

8.00

23.2

2000

18

41/0.16

1.18

3

0.76

2.75

Al-mylar

41/0.16

Tinned coppe

0.76

8.40

23.2

2000

18

41/0.16

1.18

4

0.76

2.75

Al-mylar

41/0.16

Tinned coppe

0.76

9.20

23.2

2000

18

41/0.16

1.18

5

0.76

2.75

Al-mylar

41/0.16

Tinned coppe

0.76

9.90

23.2

2000

18

41/0.16

1.18

6

0.76

2.75

Al-mylar

41/0.16

Tinned coppe

0.76

10.80

23.2

2000

18

41/0.16

1.18

7

0.76

2.75

Al-mylar

41/0.16

Tinned coppe

0.76

10.80

23.2

2000

18

41/0.16

1.18

8

0.76

2.75

Al-mylar

41/0.16

Tinned coppe

0.76

11.60

23.2

2000

18

41/0.16

1.18

9

0.76

2.75

Al-mylar

41/0.16

Tinned coppe

0.76

12.80

23.2

2000

18

41/0.16

1.18

10

0.76

2.75

Al-mylar

41/0.16

Tinned coppe

0.76

13.60

23.2

2000

16

26/0.254

1.49

2

0.76

3.05

Al-mylar

26/0.254

Tinned coppe

0.76

8.60

14.6

2000

16

26/0.254

1.49

3

0.76

3.05

Al-mylar

26/0.254

Tinned coppe

0.76

9.10

14.6

2000

16

26/0.254

1.49

4

0.76

3.05

Al-mylar

26/0.254

Tinned coppe

0.76

9.90

14.6

2000

16

26/0.254

1.49

5

0.76

3.05

Al-mylar

26/0.254

Tinned coppe

0.76

10.80

14.6

2000

16

26/0.254

1.49

6

0.76

3.05

Al-mylar

26/0.254

Tinned coppe

0.76

11.70

14.6

2000

16

26/0.254

1.49

7

0.76

3.05

Al-mylar

26/0.254

Tinned coppe

0.76

11.70

14.6

2000

16

26/0.254

1.49

8

0.76

3.05

Al-mylar

26/0.254

Tinned coppe

0.76

12.70

14.6

2000

16

26/0.254

1.49

9

0.76

3.05

Al-mylar

26/0.254

Tinned coppe

0.76

13.90

14.6

2000

16

26/0.254

1.49

10

0.76

3.05

Al-mylar

26/0.254

Tinned coppe

0.76

14.90

14.6

2000

Return to List